U heeft gezocht op: Transfermembranen

Highly sensitive transfer membranes use capillary action methods to separate DNA, RNA, or protein fragments for detection. Working well with the gels and buffers required for transfer and immobilization steps, the transfer membranes are durable enough to be subjected to multiple stripping, reprobing, hybridization cycles. The high-binding discs, sheets, and rolls come in various pore sizes and charges to fit any blotting techniques in molecular biology and genetic research.

Highly sensitive transfer membranes use capillary action methods to separate DNA, RNA, or protein fragments for detection. Working well with the gels and buffers required for transfer and immobilization steps, the transfer membranes are durable enough to be subjected to multiple stripping, reprobing, hybridization cycles. The high-binding discs, sheets, and rolls come in various pore sizes and charges to fit any blotting techniques in molecular biology and genetic research.


27  results were found

SearchResultCount:"27"

Sort Results

List view Easy View (new)

Rate These Search Results

Catalogus nummer: (MILFHATF85R)
Leverancier: Merck
Omschrijving: <p>1 roll, 8,5 cm × 10 m, 0,45 µm pore size, Triton-free, mixed cellulose esters transfer membrane.</p>
UOM: 1 * 1 ROL

New Product


Leverancier: Cytiva (Formerly Pall Lab)
Omschrijving: Biodyne® Transfer Membranes bieden hoge gevoeligheid en lage achtergrond voor verbeterde detectie en resolutie. Ze zijn ideaal voor detectie van nucleïnezuren.

New Product

Leverancier: Merck
Omschrijving: Immobilon®-P, Immobilon-P blotting sandwich transfer membranes, 7×8,4 cm

Leverancier: Merck
Omschrijving: <p>Immobilon-NC (HATF) membrane is composed of a mixed cellulose esters matrix. It is devoid of surfactants that may interfere with cell wall integrity during cell growth</p>

Leverancier: Merck
Omschrijving: <p>These Immobilon® PVDF membranes, each optimised for different protein blotting applications.</p>

Leverancier: Thermo Fisher Scientific
Omschrijving: Nitrocellulose membranes are a popular matrix used in protein blotting because of their high protein-binding affinity, compatibility with a variety of detection methods (chemiluminescence, chromogenic, and fluorescence), and the ability to immobilise proteins, glycoproteins, or nucleic acids. Protein immobilisation is thought to occur by hydrophobic interactions, and high salt and low methanol concentrations help improve protein immobilisation to the membrane during electrophoretic transfer, especially for proteins with higher molecular weights. Nitrocellulose membranes are not optimal for electrophoretic transfer of nucleic acids, as the high salt concentrations that are required for efficient binding will effectively elute some or all of the charged nucleic acid fragments.

Catalogus nummer: (PIER77015)
Leverancier: Thermo Fisher Scientific
Omschrijving: Biodyne™ A nylon membranes are sheets of unmodified nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods. Biodyne™ A nylon membrane is manufactured with a matrix pore size of 0,45 micron. It contains both negatively and positively charged groups, enabling it to bind many kinds of macromolecules.
UOM: 1 * 25 ST


Leverancier: THERMO OWL SCIENTIFIC
Omschrijving: Hydrophobic polyvinylidene fluoride transfer membrane has a high signal-to-noise ratio, which allows for the use of mild blocking procedures

Leverancier: Cytiva (Formerly Pall Lab)
Omschrijving: Van nature hydrofoob PVDF, ideaal voor een breed scala aan toepassingen voor eiwitanalyse. De familie van FluroTrans®-media zijn witte, microporeuze dragers in vaste fase die eiwitten hardnekkig binden via hydrofobe interacties. FluoroTrans®-membraan is geoptimaliseerd voor N-terminale eiwitsequencing. FluoroTrans® W-membranen zijn geoptimaliseerd voor westerse transfertoepassingen. Ze maken gevoelige eiwitdetectie mogelijk met een lage achtergrond en een zeer lage doorbranding van eiwitten. Geïmmobiliseerde eiwitten kunnen visueel worden gedetecteerd met Coomassie® Blue, Amido black, Ponceau S en colloïdaal goud.

Leverancier: Thermo Fisher Scientific
Omschrijving: Transfer membranes made of high quality PVDF, which provides high binding capacity for proteins and nucleic acids.

Catalogus nummer: (PIER77016)
Leverancier: Thermo Fisher Scientific
Omschrijving: Biodyne™ B nylon membranes are sheets of positively charged nylon that provide excellent binding characteristics for nucleic acid transfer, blotting and detection methods. Biodyne™ B nylon membrane is manufactured with a matrix pore size of 0,4 micron. It contains exclusively positive charges, providing the highest possible binding capacity for negatively charged molecules, like DNA and RNA.
UOM: 1 * 25 ST


Leverancier: Whatman products (Cytiva)
Omschrijving: Protran® membranes are manufactured from 100% pure nitrocellulose to ensure the highest binding capacity possible. They are compatible with a variety of detection methods, including isotopic, chemiluminescent, colorimetric and fluorescent. No methanol pre-wetting step is required, making this the membrane of choice for proteins which prefer aqueous environments. Prior to transfer the membrane is simply wetted with water, and then placed in the transfer buffer. No other pre treatment steps are necessary.

Leverancier: Whatman products (Cytiva)
Omschrijving: Nytran® SuPerCharge (SPC) nylon membranen hebben een zeer hoge positieve lading en een hogere dichtheid van nylon per oppervlakte-eenheid. Beschikbaar als cirkels, vellen of rollen voor microplaten.

Leverancier: G-Biosciences
Omschrijving: Pre-cut transfer membranes and padding for Western blot transfer procedures. Pre-cut membranes are supplied sandwiched between blotting paper padding. Simply soak the membrane in transfer buffer and assemble with the gel in a transfer cassette. Nitrocellulose (0,22 µm pore size) and PVDF (0,45 µm pore size) membranes are available.

Leverancier: Whatman products (Cytiva)
Omschrijving: The Nytran® Nylon (Nytran® N) membrane is ideal for applications that require a lower charge. It is designed for Southern and Northern blotting as well as colony and plaque lifts and Dot or Slot Blots. Nytran® N is compatible with isotopic detection methods.

Leverancier: Cytiva
Omschrijving: Amersham Hybond™-N+ is een positief geladen nylonmembraan met een bindingscapaciteit voor nucleïnezuren tot maximaal 600 µg/cm², aanbevolen voor gebruik bij radioactieve of niet-radioactieve chemiluminescentie- en chemifluorescentiedetectiesystemen.

Bel voor prijs
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
Stock for this item is limited, but may be available in a warehouse close to you. Please make sure that you are logged in to the site so that available stock can be displayed. If the call is still displayed and you need assistance, please call us at 1-800-932-5000.
This product is marked as restricted and can only be purchased by approved Shipping Accounts. If you need further assistance, email VWR Regulatory Department at Regulatory_Affairs@vwr.com
-Additional Documentation May be needed to purchase this item. A VWR representative will contact you if needed.
Dit artikel is geblokkeerd voor uw organisatie. Neem contact op met uw inkoopafdeling voor meer informatie
Het orginele artikel is niet langer beschikbaar. Het alternatief dat wordt getoond is beschikbaar
Product(en) gemarkeerd met dit symbool worden niet meer verkocht cq verkocht tot het einde van de voorraad. Alternatieven zijn mogelijk beschikbaar door te zoeken met het VWR-catalogusnummer dat hierboven wordt vermeld. Voor meer informatie kunt u contact opnemen met customer service: 020-4808410.
1 - 16 of 27
no targeter for Bottom